Transmit parameter sets – Lenze EMZ9371BC User Manual

Page 79

Advertising
background image

Parameterisation 8200 vector/8200 motec

Transmit parameter sets

7

EDK9371BC DE/EN/FR 3.1

79

l

H1 Parametrierung 8200−9371BC_6L

Transmit parameter sets

The keypad enables you to copy parameter settings from one standard device to another.

Use "Param managm" in menu 7 for this purpose:

Copy parameter sets from the standard device to the keypad

Step

Key sequence

Action

1.

Connect the keypad to
standard device 1

2.

Inhibit the controller

S

The drive coasts

3.

Select the "Load/Store"
submenu 7.1 in the "Param
managm" menu 7

z y Z Y

Change to the "Load/Store" submenu
using the arrow keys

4.

Change to the code level

Z

"Param managm" is displayed in C0002

5.

Change to the parameter level

V

"0" and "READY" are displayed

6.

Select the correct copy function

The settings stored in the keypad are
overwritten.

l

Copy all available parameter sets (PAR1 ... PAR4, FPAR1 if applicable) into the keypad:

– Standard device with

function module
Application I/O,
INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen

z

Copy PAR1 ... PAR4 and FPAR1:

ð

Set "80" "F1&PAR1−4−>Key"

– Standard device with all

other function modules

Copy PAR1 ... PAR4:

ð

Set "20" "PAR1−4−>Keypad"

l

Only copy the module−specific parameter set FPAR1 to the keypad:

– Only possible for

standard devices with
function module
INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen:

z

Copy FPAR1:

ð

Set "50" "FPAR1−>Keypad"

Advertising