Remote parameterisation of system bus devices – Lenze EMZ9371BC User Manual

Page 87

Advertising
background image

Parameterisation 8200 vector/8200 motec

Remote parameterisation of system bus devices

7

EDK9371BC DE/EN/FR 3.1

87

l

H1 Parametrierung 8200−9371BC_6L

Remote parameterisation of system bus devices

If controllers are networked via system bus (CAN) it is possible to remotely parameterise all
other system bus participants from one central place of the network.

For this purpose use the menu "Remote para":

Step

Keys

Action

1.

Select menu 3 "Remote para"

z y Z Y

Change to the menu "Remote para" with
the arrow keys

2.

Change to the code level

Z

Display of code C0370 "CANremot para"

3.

Change to parameter level

V

Display of the current parameter value:
"0" = OFF

4.

Set the node address of the
system bus participant you
want to parameterise

A

z

Select node address
Display of "Nodexx"

B

T V

Confirm node address

5.

Change to the code level

A

V

Display of operation level

B

V

Display of C0370 "CANremot para"

6.

Set parameters

All settings are directed to the selected
system bus participant

7.

Parameterise remotely other
system bus participants, if
necessary

Restart "loop" at step 1.

Do not forget to switch off the remote parameter setting after having completed the settings:

8.

Select menu 3 "Remote para"

z y Z Y

Change to the menu "Remote para" with
the arrow keys

9.

Change to the code level

Z

Display of code C0370 "CANremot para"

10.

Change to parameter level

V

Display of the node address "Nodexx"
activated last

11.

Switch off the remote
parameter setting

y

Set "0" = OFF

The remote parameter setting is completed