Lenze EMZ9371BC User Manual
Page 84

Parameterisation 8200 vector/8200 motec
Restoring default (as delivered) settings
EDK9371BC DE/EN/FR 3.1
84
l
H1 Parametrierung 8200−9371BC_6L
Action
Key sequence
Step
l
Load parameter sets (PARx and FPAR1):
– Restore the delivery
status in the selected
parameter set of the
standard device and the
fieldbus function
module
z
Load PAR1 and FPAR1
ð
Set "61" "Key−>FP1&PAR1"
Load PAR2 and FPAR1
ð
Set "62" "Key−>FP1&PAR2"
Load PAR3 and FPAR1
ð
Set "63" "Key−>FP1&PAR3"
Load PAR4 and FPAR1
ð
Set "64" "Key−>FP1&PAR4"
7.
Start copying
T V
The selected parameter sets are loaded
into the standard device or into the
function module.
"LOADING..." is displayed.
If "LOADING..." goes out, the loading
process has been completed.
8.
Change to the code level
A
V
The operating level is displayed
B
V
"Param managm" is displayed in C0002
9.
Enable the controller
U
The drive restarts