Outputs_aif2, 9300 servo plc, System blocks – Lenze DDS Target 9300 Servo PLC V8.x User Manual

Page 23: 2 outputs_aif2, 2 aif2_io_automationinterface (node number 42)

Advertising
background image

9300 Servo PLC

System blocks

2.2

AIF2_IO_AutomationInterface (node number 42)

2−17

L

9300 Servo PLC EN 5.1

2.2.2

Outputs_AIF2

This SB is used as an interface for output signals (e.g. setpoints/actual values) to attached fieldbus
modules (e.g. INTERBUS, PROFIBUS−DP).

·

The process image is
– created in the cyclic task in a fixed time interval of 10 ms.
– created in an interval task within the time set for this task.
– read at the beginning of the task and written at its end.

Tip!

Please observe the Operating Instructions for the attached fieldbus module.

Outputs_AIF2

Automation

Interface

...

Byte

1

Byte

2

Byte

3

Byte

4

Byte

5

Byte

6

Byte

7

Byte

8

...

16 Bit

LowWord

16 Bit

HighWord

16 Bit

16 binary

signals

16 Bit

16 binary

signals

AIF2_nOutW2_a

AIF2_nOutW1_a

AIF2_bFDO0_b

AIF2_bFDO15_b

AIF2_bFDO16_b

AIF2_bFDO31_b

16 Bit

16 Bit

AIF2_nOutW4_a

AIF2_dnOutD1_p

AIF2_nOutW3_a

Fig. 2−4

Outputs_AIF2