Technical data 2 technical data, 1 electrical characteristics, Single-phase models – Lenze E94P PositionServo with MVOB User Manual

Page 12: Single/three-phase models

Advertising
background image

10

L

S94H201E_13426446_EN

Technical Data

2 Technical Data

2.1

Electrical Characteristics

Single-Phase Models

Type

(1)

Mains Voltage

(2)

1~ Mains

Current

(doubler)

1~ Mains

Current

(Std.)

Rated

Output

Current

(5)

Peak

Output

Current

(6)

E94_020S1N_~

120V

(3)

or 240V

(4)

9.7

5.0

2.0

6

E94_040S1N_~

15

8.6

4.0

12

E94_020S2F_~

120 / 240V

(4)

(80 V -0%...264 V +0%)

--

5.0

2.0

6

E94_040S2F_~

--

8.6

4.0

12

E94_080S2F_~

--

15.0

8.0

24

E94_100S2F_~

--

18.8

10.0

30

Single/Three-Phase Models

Type

(1)

Mains Voltage

(2)

1~

Mains

Current

3~

Mains

Current

Rated

Output

Current

(5)

Peak

Output

Current

(6)

E94_020Y2N_~

120 / 240V

(4)

1~ or 3~

(80 V -0%...264 V +0%)

5.0

3.0

2.0

6

E94_040Y2N_~

8.6

5.0

4.0

12

E94_080Y2N_~

15.0

8.7

8.0

24

E94_100Y2N_~

18.8

10.9

10.0

30

E94_120Y2N_~

24.0

13.9

12.0

36

E94_180T2N_~

240V 3~

(180 V -0%...264 V +0%)

--

19.6

18.0

54

E94_020T4N_~

400 / 480V

3~

(320 V -0%...528 V +0%)

--

2.7

2.0

6

E94_040T4N_~

--

5.5

4.0

12

E94_060T4N_~

--

7.9

6.0

18

E94_090T4N_~

--

12.0

9.0

27

(1)

The first “_” equals “P” for the 940 encoder based drive or “R” for the 941 resolver based drive.

The second “_” equals “E” for incremental encoder (must have E94P drive) or “R” for the standard resolver (must have E94R drive).

The last digit “~” equals “M” for MV OnBoard and no ISO 13849-1 circuit or “S” for MV OnBoard plus the ISO 13849-1 circuit.

(2)

Mains voltage for operation on 50/60 Hz AC supplies (48 Hz -0% … 62Hz +0%).

(3)

Connection of 120VAC (70 V … 132 V) to input power terminals L1 and N on these models doubles the voltage on motor output

terminals U-V-W for use with 230VAC motors.

(4)

Connection of 240VAC or 120VAC to input power terminals L1 and L2 on these models delivers an equal voltage as maximum to motor
output terminals U-V-W allowing operation with either 120VAC or 230VAC motors.

(5)

Drive rated at 8kHz Carrier Frequency. Derate Continuous current by 17% at 16kHz.

(6)

Peak RMS current allowed for up to 2 seconds. Peak current rated at 8kHz. Derate by 17% at 16kHz.

(7)

Derate rated output current and peak output current by 2.5% for every ºC above 40ºC up to 55ºC maximum.

Advertising