Parameters, 11 faults – Lenze E94P PositionServo with MVOB User Manual

Page 63

Advertising
background image

S94H201E_13426446_EN

L

61

Parameters

To edit a parameter’s value, double click the [Decimal] field of the parameter. When the text is double-
clicked, the background color will change. The parameter value will stop updating allowing you to change
the value. However, if the interface device or user’s program manipulates the value of the parameter, then
your change will be overwritten in a concurrent manner.

Parameter I/O View with Variables

NOTE
By clicking [#], the variables can be automatically sorted in descending or ascending order. They can
also be sorted alphabetically by clicking [Variable Name] and/or [Short Name].

NOTE
Write-only variables may not contain valid data in the “Parameter and I/O” view screen as all write-
only variables in the drive use a common display buffer.

5.11 Faults

The [Faults] folder contains three action buttons upon opening and displays the most recent fault. [Load
Faults] permits the user to load the entire stored fault history of the drive onto the computer. The sixteen
most recent faults are displayed with the newer faults replacing the older faults in a first-in, first-out
manner. In all cases, the fault on top of the list is the most recent fault. [Clear Faults] clears the fault history
of the drive from within the MotionView program. The device time of the fault is the time from last power up
(Power-up time = 00:00). Each fault has its code and explanation of the fault. Refer to section 8.4 for details
on faults. [Clear Fault/Reset] clears the active fault and resets the drive.