L

S94H201E_13426446_EN

Diagnostics

Fault Code

(Display)

Fault

Description

F_26

Unknown

byte code

Byte code interpreter error; May occur when program is missing the closing END

statement; when subroutine has no RETURN statement; or if data in EPM is corrupted at

run-time

F_27

Drive disabled

Attempt to execute motion while drive is disabled. Drive programming error (error in drive

source code).

F_28

Accel too high

Motion statement parameters calculate an Accel value above the system capability. Drive

programming error (error in drive source code).

F_29

Accel too low

Motion statement parameters calculate an Accel value below the system capability. Drive

programming error (error in drive source code).

F_30

Velocity too high

Motion statement parameters calculate a velocity above the system capability. Drive

programming error (error in drive source code).

F_31

Velocity too low

Motion statement parameters calculate a velocity below the system capability. Drive

programming error (error in drive source code).

F_32

Positive Limit Switch

Positive limit switch is activated.

(Only available while drive is in position mode)

F_33

Negative Limit Switch

Negative limit switch is activated.

(Only available while drive is in position mode)

F_34

Positive motion w/ Pos

Lim Sw ON

Attempt at positive motion with engaged positive limit switch

F_35

Negative motion w/ Neg

Lim Sw ON

Attempt at negative motion with engaged negative limit switch

F_36

Drive Disabled by User

at Enable Input

The drive is disabled while operating or an attempt is made to enable the drive without

deactivating “Inhibit input”. “Inhibit” input has reverse polarity

F_37

Under voltage

(Applies to drive’s with hardware version 2 and higher). Occurs when the bus voltage
level drops below 50% of nominal bus voltage while drive is operating. An attempt to

enable the drive with low bus voltage will also result in this fault.

F_38

EPM Loss

EPM Failure

F_39

Positive soft limit

reached

Programmed (Soft) absolute limits reached during motion

F_40

Negative soft limit

reached

Programmed (Soft) absolute limits reached during motion

F_41

Unknown Variable ID

Attempt to use variable with unknown ID from user program. Drive programming error

(error in drive source code).

F_42

Missing Hardware

Ethernet port failure.

F_43

DeviceNet Module Error

DeviceNet module configured but not detected.

F_44

Bad Memory Index

Memory index out of limits when writing user variables to RAM.

F_45

2nd Encoder Position

Error

Secondary encoder position error limit has exceeded maximum value (applies to

hardware version 1)

F_46

PFB module error

PROFIBUS module configured but not detected.

F_47

PFB monitor timeout

PROFIBUS network monitor timeout error.

F_48

PFB exchange timeout

PROFIBUS data exchange timeout error.

F_49

Illegal manipulation

of APOS

The APOS variable cannot be manipulated while a MOVE is being executed

F_51

Unspecified DSP fault

General internal fault.

F_52

Drive disabled-motion

Drive disabled while in motion.