Interface, Ccw cw a b, 2 digital i/o details – Lenze E94P PositionServo with MVOB User Manual

Page 33: Ccw cw direction step

Advertising
background image

S94H201E_13426446_EN

L

31

Interface

4.2

Digital I/O Details

4.2.1

Step & Direction/Master Encoder Inputs (P3, pins 1-4)

A master encoder with quadrature outputs or a step and direction pair of signals can be connected to the
PositionServo to control position in the external positioning operating mode. These inputs are optically
isolated from the rest of the drive circuits and from each other. Both inputs can operate from any voltage
source in the range of 5 to 24 VDC and do not require additional series resistors for normal operation.

CCW

CW

DIRECTION

STEP

S904

Timing Diagram for Step & Direction Signals

CCW

CW

A

B

S905

Timing Diagram for Master Encoder Signals

Input type/output compatibility

Insulated, compatible with single-ended or differential outputs
(5-24 VDC)

Max frequency (per input)

2 MHz

Min pulse width (negative or positive) 500nS
Input impedance

700

(approx)

MA+/STEP+

MB+/DIR+

MA-/STEP-

MB-/DIR-

600

100

5.6V

S906

Master Encoder Step & Direction Input Circuit

Differential signal inputs are preferred when using Step and Direction. Single ended inputs can be used but
are not recommended. Sinking or sourcing outputs may also be connected to these inputs. The function of
these inputs “Master Encoder” or “Step and Direction” is software selectable. Use the MotionView set up
program to choose the desirable function.

Advertising