Interface

Test
Step

Action

Drive Display
Indication

Safety Status Output
Indication

Failed Test
Indication

5

Deactivate Safety
Input 2. Set Input A3
to Enable

‘F EF’

‘Activated’

No Trip on display (F_EF) = Safety Input 2 failed to deactivate.
Status Output Deactivated = Safety Input 1 Failed to activate

6

Set Input A3 to disable

‘Dis’

‘Activated’

Status Output Deactivated = Both Safety Inputs Failed to
activate

7

Deactivate Safety
Input 1. Set Input A3
to Enable

‘F EF’

‘Deactivated’

No Trip on display (F_EF) = Safety Inputs 1 & 2 failed to
deactivate.
Status Output Activated = Safety Input 1 or Safety Input 2
Failed to deactivate

This procedure will evaluate the following conditions:

a.

All Circuits (safety inputs 1 & 2) working Correctly

b.

Safety Input 1 failing to activate

c.

Safety Input 1 failing to deactivate

d.

Safety Input 2 failing to activate

e.

Safety Input 2 failing to deactivate

f.

Both Safety input 1 and 2 failing to activate

g.

Both Safety input 1 and 2 failing to deactivate

Electrical Characteristics

Safety Input1, Safety Input2 and Safety Status are fully isolated from the rest of the drive circuits as shown
in the following diagram.

Safety Inputs

Insulated, compatible with single-ended output (+24VDC)

Enable voltage range: 18 to 30VDC

Disable voltage range: 0 to 1.0 VDC

Input Impedance

6.8 k

Safety Status

Isolated Open Collector (Grounded Emitter)

Output Load Capability

100mA

Output Max Voltage

30VDC (Collector-Emitter)

Safety Status

Safety Input 2

Safety Input 1

Safety COM

SAFETY COM

SAFETY COM

SAFETY COM

6.8kΩ

6.8kΩ

1

1

1

2

2

2

3

3

3

4

4

4

A

A

A

C

C

C

E

E

E

K

K

K

Advertising