11 .5 speed pot and preset speed control – Lenze TCF Series User Manual

Page 28

Advertising
background image

11 .5

SPEED POT AND PRESET SPEED CONTROL

This wiring diagram illustrates SPEED POT and/or PRESET SPEED control with a two-wire
start/stop circuit .

MAINTAINED

RUN FORWARD

CONTACT

SIGNAL

COMMON

0-10

VDC

INPUT

DIGITAL

INPUT

REFERENCE

RUN

FORWARD

PRESET

SPEED

SELECT

1

2

5 6

14

TXA TXB

4

13A 13B 13C

4

13D

25

11

15

30

2

DIGITAL

INPUT

REFERENCE

PRESET

SPEED

SELECT

PRESET

SPEED

SELECT

10

VDC

SUPPLY

SPEED POT

(2 .5k - 10 kΩ)

NOTES
• Program the PRESET SPEEDS (Parameters 31-37) to the desired

values .

• Program TB-13A (Parameter 10) to PRESET SPEED #1 (04), TB-13B

(Parameter 11) to PRESET SPEED #2 (04), and TB-13C (Parameter
12) to PRESET SPEED #3 (04) . To select a preset speed, close the
appropriate TB-13 terminal(s) to TB-4 (refer to Parameters 31-37 for the
Preset Speed Activation table) .

• For speed pot control, program Parameter 05 - STANDARD REFERENCE

SOURCE for 0-10 VDC (03) . If none of the preset speeds are selected (all
of the TB-13 terminals are open), the drive will respond to the speed pot .

24