Lenze TCF Series User Manual

Page 72

Advertising
background image

B.5

DESCRIPTION OF ASSERTION LEVEL FAULTS

Along with the "A1" fault described above, there are a few other faults associated with the
drive's assertion level . Refer to the following table .

FAULT

DESCRIPTION, CAUSES & REMEDIES

AL

Internal

AL

Occurs whenever the internal assertion level setting has been changed,
regardless of the cause . This fault can be cleared by giving the drive a STOP
command .

A1

EPM

AL

The assertion level setting stored in the EPM does not match the internally
stored setting . Refer to Appendix B, section B .4 .

A2

OEM AL
stored in

EPM

Occurs if the OEM Defaults assertion level stored on the EPM does not match
the internally stored setting, and an attempt is made to select setting “02” or
“03” in Parameter 48 -PROGRAM SELECTION . This fault can be cleared by
giving the drive a Stop command . To prevent this fault, install an EPM with the
correct OEM Defaults settings .

A3

Internal

AL

Corrupt

Occurs if the internally stored assertion level setting is corrupted . In this case,
the assertion level will default to active-high (P79 = “01”) . This fault can be
cleared by performing a reset using Parameter 48 - PROGRAM SELECTION,
or by installing an EPM that was just programmed with the desired assertion
level using the EPM Programmer (refer to NOTE 1 in Appendix B, section
B .3 .2) .

A4

Control

Board

Failure

“A4” indicates a failure on the control board . A new control board is required .

68

Advertising