BIPOLAR SPEED CONTRO L (-10 to +10 VDC)

The three wiring diagrams herein provide examples of using a -10 to +10 VDC bipolar speed
reference .

SIGNAL

COMMON

0-10

VDC

INPUT

1 2 5 6 11

-10 to +10 VDC

SOURCE

(such as PLC)

SIGNAL

COMMON

0-10

VDC

INPUT

1 2 5 6 11

10V

10V

SPEED POT

(2 .5k - 10 kΩ)

-

+ -

+

SIGNAL

COMMON

0-10

VDC

INPUT

1 2 5 6 11

+10

VDC

SUPPLY

10V

SPEED POT

(2 .5k - 10 kΩ)

-

+

(COM) (SIGNAL)

NOTES:
• To use a -10 to +10 VDC speed reference signal, the following parameters

must be set:

P07 BIPOLAR REFERENCE SELECTION must be set to ENABLE (02) .
P17 ROTATION must be set to FORWARD AND REVERSE (02) .
P45 SPEED AT MIN SIGNAL must be set to the maximum desired

speed in the reverse direction .

P46 SPEED AT MAX SIGNAL must be set to the maximum desired

speed in the forward direction .

• In this configuration, all other speed references are disabled except JOG

FORWARD and JOG REVERSE .

• In this configuration, the RUN and START functions on TB-13A and

TB-13D will only start the drive, they will not select direction . Direction is
determined by the polarity of the -10 to +10 VDC signal .