NO. PARAMETER NAME

RANGE OF ADJUSTMENT

FACTORY

DEFAULT

(NOTE 1)

28

FIXED BOOST

0 .0 - 30 .0 %

1 .0 %

29

ACCEL BOOST

0 .0 - 20 .0 %

0 .0 %

30

SLIP COMPENSATION

0 .0 - 5 .0 %

0 .0 %

31-37

PRESET SPEEDS

0 .0 - MAXIMUM FREQUENCY

0 .0 Hz

38

SKIP BANDWIDTH

0 .0 - 10 .0 Hz

0 .0 Hz

39

SPEED SCALING

0 .0 - 6500 .0

0 .0

40

FREQUENCY SCALING

3 .0 - 1200 .0 Hz

60 .0 Hz

41

LOAD SCALING

10 - 200 %

200 %

42

ACCEL/DECEL #2

0 .1 - 1300 .0 SEC

20 .0 SEC

43

SERIAL ADDRESS

1 - 247

1

44

PASSWORD

000 - 999

225

45

SPEED AT MIN SIGNAL

0 .0 - 999 Hz

0 .0 Hz

46

SPEED AT MAX SIGNAL

0 .0 - 999 Hz

60 .0 Hz

47

CLEAR HISTORY

MAINTAIN (01), CLEAR (02)

MAINTAIN (01)

48

PROGRAM SELECTION

USER SETTINGS (01), OEM SETTINGS (02),

USER SETTINGS

(01)

RESET OEM (03), RESET 60 (04),

RESET 50 (05), TRANSLATE (06)

49

TB-13D

FUNCTION SELECT

NONE (01), 0-10 VDC (02), 4-20 mA (03),

NONE (01)

PRESET SPEED #1 (04),

START FORWARD (05),

EXTERNAL FAULT (06),

REMOTE KEYPAD (07), DB FAULT (08),

AUXILIARY STOP (09), ACCEL/DECEL #2 (10)

50

SOFTWARE CODE

(VIEW-ONLY)

(N/A)

51

SOFTWARE CODE

(VIEW-ONLY)

(N/A)

52

DC BUS VOLTAGE

(VIEW-ONLY)

(N/A)

53

MOTOR VOLTAGE

(VIEW-ONLY)

(N/A)

54

LOAD

(VIEW-ONLY)

(N/A)

55

0-10 VDC INPUT

(VIEW-ONLY)

(N/A)

56

4-20 mA INPUT

(VIEW-ONLY)

(N/A)

NOTE 1: Factory defaults are shown for a 60 Hz base frequency . Refer to Parameter 48 for 50 Hz base frequency .