NO. PARAMETER NAME

RANGE OF ADUSTMENT

FACTORY

DEFAULT

(NOTE 1)

11

TB-13B FUNCTION

SELECT

NONE (01), 0-10 VDC (02), 4-20 mA (03),

NONE (01)

PRESET SPEED #2 (04), DECREASE FREQ (05),

JOG FORWARD (06), AUXILIARY STOP (07)

12

TB-13C FUNCTION

SELECT

NONE (01), 0-10 VDC (02), 4-20 mA (03),

NONE (01)

PRESET SPEED #3 (04), INCREASE FREQ (05),

EXTERNAL FAULT (06), REMOTE KEYPAD (07),

DB FAULT (08), JOG REVERSE (09),

ACCEL/DECEL #2 (10)

13

TB-15 OUTPUT

(SEE PARAMETER 6 - TB-14 OUTPUT)

NONE (01)

14

CONTROL

TERMINAL STRIP ONLY (01),

TERMINAL STRIP

ONLY (01)

REMOTE KEYPAD ONLY (02),

TERMINAL STRIP OR REMOTE KEYPAD (03)

15

SERIAL LINK

DISABLE (01), 9600, 8, N, 2 WITH TIMER (02),

9600, 8, N, 2 WITHOUT TIMER (03),

9600, 8, E, 1 WITH TIMER (04),

9600, 8, N, 2

9600, 8, E, 1 WITHOUT TIMER (05),

WITH TIMER (02)

9600, 8, O, 1 WITH TIMER (06),

9600, 8, O, 1 WITHOUT TIMER (07)

17

ROTATION

FORWARD ONLY (01),

FORWARD

FORWARD AND REVERSE (02)

ONLY (01)

18 MTR OVERLOAD TYPE

SPEED COMP (01), NO COMP (02)

SPEED COMP (01)

19

ACCELERATION TIME

0 .1 - 1300 .0 SEC

20 .0 SEC

20

DECELERATION TIME

0 .1 - 1300 .0 SEC

20 .0 SEC

21

DC BRAKE TIME

0 .0 - 999 .0 SEC

0 .0 SEC

22

DC BRAKE VOLTAGE

0 .0 - 30 .0 %

0 .00%

23 MINIMUM FREQUENCY

0 .0 - MAXIMUM FREQUENCY

0 .0 Hz

24 MAXIMUM FREQUENCY

MINIMUM FREQ - 240 .0 Hz

60 .0 Hz

25

CURRENT LIMIT

50 - 200 % (NOTE 2)

200%

26

MOTOR OVERLOAD

30 - 100 %

100%

27

BASE FREQUENCY

25 .0 - 500 .0 Hz

60 .0 Hz

NOTE 1: Factory defaults are shown for a 60 Hz base frequency . Refer to Parameter 48 for 50 Hz base frequency .
NOTE 2: If LINE VOLTAGE is set to LOW, maximum setting is 167% .