Technical data

Rated data

Rated data of the extra-low voltage version (24 or 42 V DC)

3

18

GHB 13.0002-EN 3.1

3.3.3

Rated data of the extra-low voltage version (24 or 42 V DC)

Theextra-lowvoltageversionofthedriveshasbeendesignedforoperationon24/42 VDC.

For a simple servo inverter operation, a 24 V or 42 V supply is sufficient. With an additional

24 V auxiliary supply, the control continues to be supplied if an error occurs and the supply

voltage is disconnected. Important data (rotor position, information on faults, etc.) will

thus continue to be recorded and transferred to the control.

Note!

The residual ripple component of the supply voltage must be under 5%.

The24 Vauxiliarysupplyisalsorequiredifthedigitalinterface(digitalI/O)orthe localCAN

interface is used.

3.3.4

Rated data of the low-voltage version (230 V AC / 320 V DC)

Inverterswith 230 V AC mainssupply have an additional 24 V auxiliarysupply. The control

is also supplied by the mains voltage. With an additional 24 V auxiliary supply, the control

continues to be supplied if an error occurs and the supply voltage is disconnected.

Important data (rotor position, information on faults, etc.) will thus continue to be

recorded and transferred to the control.
The24 Vauxiliarysupplyisalsorequiredifthedigitalinterface(digitalI/O)orthe localCAN

interface is used.