Electrical installation

Important notes

5

28

GHB 13.0002-EN 3.1

5

Electrical installation

5.1

Important notes

Stop!

The drive controller contains electrostatically sensitive components.
The personnel must be free of electrostatic charge prior to assembly and

service operations.

Danger!

ƒ

The connection of all pluggable terminals has to be effected in a

deenergised state.

ƒ

Connecting and disconnecting the voltage supply (X2) due to the charging

processes of the intermediate circuit capacitor may cause traces of burning

on the wrap connection, and may result in a destruction of the internal

electronic circuit.

ƒ

A false polarity of the DC supply can bring about the destruction of the

drive. Before switching the drive on, ensure that the polarity of the

DC supply is correct.

Note!

For trouble-free operation, the following conditions are required:

ƒ

An installation according to EMC.

ƒ

The shield of the motor cable has to be connected to PE potential as

extensively as possible to prevent effects due to interference.

ƒ

The resolver cable, encoder cable, and the motor cable may have a length of

10 m at a maximum!

ƒ

The feeding power supply units have to be sufficiently dimensioned. The

power supply units have to be protected against overcurrent by means of

appropriate input fuses.

Advertising