Troubleshooting and fault elimination – Lenze 931W User Manual

Page 47

Advertising
background image

Troubleshooting and fault elimination

Fault elimination for known error message (see Fluxx, ”Status” tab)

8

47

GHB 13.0002-EN 3.1

Remedy

Cause

Error message
Definition of software limit switch

Error concerning the definition of the

software limit switch

Check on whether left software limit

switch < right software limit switch

Consider positive direction (”System” tab)

as well as possible gearbox direction

inversion (”Service” tab)

Check settings of the software limit

switches

Drive inhibited

Mechanical load too high (output shaft

inhibited)

Check mechanical load

Check and, if required, increase maximum

torque in the ”Service”, ”Controller” and

”Travel data set” tabs

Brake in the ”Service” tab is not

selected/not released

Check setting of the mechanical brake

(recommendation: 150 ms for

disengagement and engagement time)

Check function of the brake (releasing and

disengaging of the brake has to be

audible). In case of faulty behaviour,

address the manufacturer

Connection error in the motor cable

Select the option ”Resolver direction

inversion” in the ”Service” tab

Exchange of 2 phases of the connection

(e. g. ”V/U/W” instead of ”U/V/W”)

No resolver position adjustment

Carry out resolver position adjustment

(”Service” tab)

Internal error

Internal error

Output stage of the drive is defective,

return drive to the manufacturer

Position encoder

The feedback system indicates an error

Return the drive to your sales partner

Advertising