Technical data – Lenze 931W User Manual

Page 21

Advertising
background image

Technical data

Rated data

Rated data for S3 operation/overload capacity

3

21

GHB 13.0002-EN

3.1

3.3.6

Rated data for S3 operation/overload capacity

For the dimensioning of a drive system which is operated in S3 operation, the effective

motor torque is to be calculated. The effective torque results from the kinematics (travel

profile) and the time-dependent load profile in consideration of the gearbox ratio,

efficiency, friction lossses, etc.. It can be calculated in a simplified manner according to the

following equation, where T represents the period of a cycle and Mi the motor torque to

be reached in the time t

i

. Furthermore, a dynamic factor k

dyn

is to be considered, which -

depending on the dynamic of the load profile - can reach values between 1 (low dynamic)

to 1.2 (high dynamic / strong stabilisation processes). For calculating the effective torque,

or for dimensioning drive systems, the ”Drive Solution Designer” program can be used.

M

eff

=

t

i

⋅ M

2

i

T

⋅ k

dyn

≤ M

rated

The drives of the 930 fluxxtorque product range are checked with regard to the S3

operating mode according to the load profile represented in diagram 1. The load profile

travelled at rated speed (cycle time: 5 s) is composed of a peak load of 0.5 s (150 % M

rated

)

and a recovery time of 4.5 s (75% M

rated

).

0.5s

4.5s

T

M

100 %

75 %

150 %

Fig. 1

Overload capacity of the drive at 40°C

Type

SDSGSSR35

SDSGSSR47

SDSGSSR56

S3 operation
Supply voltage [V]

24 *

42

42 *

230

320

230

320

Rated torque [Nm]

0.45

0.45

0.80

0.80

0.80

1.40

1.40

Max. load torque (15%) [Nm]

0.68

0.68

1.20

1.20

1.20

2.10

2.10

Recovery torque (75%) [Nm]

0.34

0.34

0.60

0.60

0.60

1.05

1.05

*

The information is based on a reduced speed (1000 U/min).

Advertising
This manual is related to the following products: