Technical data

General data and operating conditions

4

l

74

EDBMB935X DE/EN/FR 13.0

4

Technical data

4.1

General data and operating conditions

General data

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

Approval

UL

cULus

Power Conversion Equipment (File No. E132659)

Protection of persons and equipment

Enclosure

EN 60529

IP10

IP20 with mounted terminal covers

IP41 on the heatsink side for thermally separated
mounting (push−through technique).

NEMA 250

Protection against contact according to type 1

Insulation resistance

IEC/EN 61800−5−1 < 2000 m site altitude: overvoltage category III

> 2000 m site altitude: overvoltage category II

Short−circuit strength

Not short−circuit−proof

Operating conditions

Ambient conditions

Climatic

Storage

IEC/EN 60721−3−1

1K3 (−25 ... +70 °C)

Transport

IEC/EN 60721−3−2

2K3 (−25 ... +60 °C)

Operation

IEC/EN 60721−3−3

3K3 (0 ... +40 °C)

without power reduction

3K3 (+40 ... +50 °C)

with power reduction by
2.5%/ °C

Pollution

EN 61800−5−1

Degree of pollution 2

Site altitude h

h

£ 1000 m amsl

without power reduction

1000 m amsl < h <
4000 m amsl

with power reduction by
5 %/ 1000 m

Mechanical

Vibration resistance

EN 50178
EN 61800−5−1
Germanischer
Lloyd, general
conditions

Tested according to "General Vibration Stress
Characteristic 1"