Dimensioning

Calculate max. running time for brake chopper and brake resistor

5

l

78

EDBMB935X DE/EN/FR 13.0

I

rated

Rated current EMB9352, mean arithmetic value

t

on

Running time

0

Max. running time for brake resistance <R

B,lim

Condition: t

on

+ t

off

= 3 s

1

Max. running time for brake resistance

³R

B,lim

Depending on the technical data of the brake resistor

Brake resistance R

B

³ R

B,lim

: Calculate running time and dead time

t

on,max

+

Q

B

@ R

B

U

max

2

t

off

+

Q

B

P

N

* t

on,max

t

on,max

Maximum running time in s

t

off

Dead time in s

RB

Brake resistance in

W

U

max

Max. operating voltage in V

P

rated

Rated power in W

Q

B

Heat in Ws

The data can be obtained from the documentation for the brake resistor

Brake resistance R

B

< R

B,lim

: Condition for the running time and dead time

t

on,max

) t

off

+ 3 s

t

on,max

Maximum running time in s

t

off

Dead time in s