Mechanical installation

Important notes

6

l

88

EDBMB935X DE/EN/FR 13.0

6

Mechanical installation

6.1

Important notes

ƒ

Only use the braking units as built−in units!

ƒ

Observe mounting clearances!

Observe clearance of 100 mm at the top and at the bottom.

ƒ

Make sure that the cooling air can access and the exhaust air can escape
unimpededly.

ƒ

If the cooling air is polluted (dust, lints, greases, aggressive gases), which
may affect the function of the braking units:

Take adequate countermeasures, e. g. separate air guide, installation of
filter, regular cleaning, etc.

ƒ

Do not exceed the permissible range of the ambient operating
temperature (see chapter 4.1).

ƒ

If the braking units are permanently exposed to vibrations or shocks:

Check the use of vibration dampers.

Possible mounting positions

ƒ

Vertically on the rear panel of the control cabinet, power connections
facing upwards

Fixed with enclosed fixing rails (see chapter 6.2)

Thermally separated with an external heatsink ("Push−through
technique") (see chapter 6.3)

Thermally separated with an external convection cooler ("Cold plate"
technology) (see chapter 6.4)

}

Danger!

ƒ

In case of fault, brake resistors can reach very high temperatures;
the brake resistor may even burn down, e. g. in the case of
– mains overvoltage,
– application−specific overload,
– internal error.

ƒ

Therefore mount the brake resistors so that no damage can be
caused by the possible, very high temperatures.