Mechanical installation

Mounting in cold−plate design
Mounting

6

l

94

EDBMB935X DE/EN/FR 13.0

6.4.4

Mounting

Before screwing the cooler and the cooling plate of the braking unit together,
apply the heat conducting paste supplied, in order to keep the heat transfer
resistance as low as possible.

ƒ

Clean the contact surface using spirit.

ƒ

Apply the heat conducting paste in a thin layer using a spattle or a paint
brush.

The heat conducting paste in the accessory kit is sufficient to cover a
surface of approx. 1000 cm

2

.

ƒ

Mount controller to the heatsink with 4 M5 fixing screws.

Screw−tightening torque: 3.4 Nm (30 Ib−in).

a

g

c

b

d

b1

e

l

9350br_004

Fig. 9

Dimensions

Type

a

b

b1

c

d

e

g

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

9351−V003
9352−V003

52

381

350

34

367

104

6.5

Advertising