Dimensioning examples, Translatory movement, Dimensioning – Lenze EMB9352−C User Manual

Page 82

Advertising
background image

Dimensioning

Dimensioning examples
Translatory movement

5

l

82

EDBMB935X DE/EN/FR 13.0

5.4

Dimensioning examples

5.4.1

Translatory movement

A translatory movement is to be braked.
Provided data:

ƒ

U

DC

= 725 V

ƒ

Power characteristic in generator mode:

1

2

3

4

5

t [s]

5

10

15

20

25

30

35

40

45

50

55

P

gen

[kW]

0

1

9350br_16b

Fig. 4

Power characteristic in generator mode

Data provided by the diagram:

ƒ

Max. regenerative power: P

gen,max

= 55 kW

ƒ

Average regenerative power over 3 s: P

gen,ave

(3 s) = 34.375 kW

In a time range of 3 s, the highest power is provided between t = 0 … 3 s.
The mean value is calculated for this range. The circumscribed area of
the curve represents the average power.

Mean value

0for 3 s: P

gen,ave

= 13.75 kW

Mean value

1for 3 s: P

gen,ave

= (55 kW ˘ 13.75 kW) × 0.5 = 20.625 kW