Technical data

Rated data

4

l

75

EDBMB935X DE/EN/FR 13.0

4.2

Rated data

EMB9351

EMB9352

Supply voltage

U

DC

[V]

270 V − 0 % ... 775 V + 0 %

Adjustable switching
threshold(

104)

U

ch

[V]

375, 725, 765

Max. current over 1 s on; 2 s off

I

DC

[A]

16

43

Rated current

Mean arithmetic value

I

rated

[A]

˘

14

r.m.s. value

I

rated

[A]

˘

25

Data for switching threshold U

ch

= 375 V

Max. power

P

max

[kW]

3

16

Rated power
(Mean arithmetic value)

P

rated

[kW]

0.1

5

Min. brake resistance

R

B,min

[

W]

47 (internal)

9 ±10 %

1)

Data for switching threshold U

ch

= 725 V

Max. power

P

max

[kW]

11

29

Rated power
(Mean arithmetic value)

P

rated

[kW]

0.1

10

Min. brake resistance

R

B,min

[

W]

47 (internal)

18 ±10 %

1)

Data for switching threshold U

ch

= 765 V

Max. power

P

max

[kW]

12

33

Rated power
(Mean arithmetic value)

P

rated

[kW]

0.1

11

Min. brake resistance

R

B,min

[

W]

47 (internal)

18 ±10 %

1)

Maximum energy

Q

B

[kWs]

50

(4 s on; 500 s off)

(external resistor)

Mass

m [kg]

2.6

2.2

1)

Brake resistor selection: (

76)

4.3

Fuses and cable cross−sections

Type

Fuses

Cable cross−section

VDE/UL

mm

2

AWG

EMB9351

20 A/600 V

2.5

12

EMB9352

50 A/600 V

6

1)

10

1)

1)

Use terminal pinsif a flexible cable is used