Requirements
Establishing communication with the controller
14
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
• Enter the desired IP address of the controller.
[3-1]
Example: Enter the IP address of the controller.
3. Click OK to add the controller as gateway.
4. By double-clicking the desired channel (or clicking the Set active path button), set the
channel selected in the device view below the gateway as active path to the controller.
• Thus, all communication actions directly refer to this channel.
• The currently active path is represented in bold in the list and "(active)" is attached:
5. A device represented in italics is set as active path but has not been found during the last
network scan.
Note!
• During initial commissioning, observe the following predefined IP addresses of the
controllers:: 192.168.5.99
Further information can be found in the following documentation:
• Controller - Parameter setting & configuration