9.9.2

Configuring an error response

The error response types of the error handler define the state of the module's intrinsic application.

If an error occurs, the standard behaviour triggers the configured error response in the other

machine modules.
If a different error response of the machine module is desired, the possibility of programming the

desired error response in the corresponding machine module is provided.

• Further information on the DefaultCoupling (predefined standard response) can be found in the

following section:



Default coupling

( 83)

• The error states that can be defined in the module applications (MAP) are divided into the

following error categories:

9.9.3

Acknowledging errors

The acknowledgement of errors deletes all error messages / error causes that have been defined as

requiring acknowledgement from the current error list (Error List).
The acknowledgement of errors can be activated by the following procedures:

1. Permanent activation: Within the module application via the following program command:

Error text

Text description of the error.

The (English) error text is stored in the table of

attributes.

The error text always is to be used if no higher-level

mechanism for implementation of the error number

in national languages is activated (example: higher-

level visualization).

Detailed

error information

For each error, an additional

attribute (type: DWORD) can be

used, which (in connection with the

error number) can be interpreted.

For a "Drive Error" group error, for instance, the

detailed error information of the corresponding

controller can be used.

Priority

Assign priority for errors of the same error response type.

Characteristic

Description

Further information

Error response (in order of ascending

priority)

Description / acknowledgement behaviour

Information

Writes information in the logbook of the controller.

• No acknowledgement required.

Quick stop (fault)

Error response in the case of which the machine module involved changes to

the "Stop" status.

• The acknowledgement behaviour is parameterisable.

Warning

The machine module/the application remains in the same status.

• The acknowledgement behaviour is parameterisable.

Error

Causes the machine module involved to trip a response (for example setting

controller inhibit/pulse inhibit).

• The acknowledgement behaviour is parameterisable.

System fault

Fatal error.

Restart of the application required (by mains switching or device reset).

• No acknowledgement possible.