3.2.5.3
SMC_FollowVelocity
This POU writes speed setpoints to the axis and during this process does not carry out any
checks.
Inputs (VAR_INPUT)
bExecute: BOOL
By a rising edge the block starts to write the setpoints entered in fSetPosition to the axis
data structure. It remains active until it is interrupted by another block (e.g. MC_Stop).
fSetVelocity: LREAL
Setpoint speed in technical units per second.
Outputs (VAR_OUTPUT)
bBusy : BOOL (Default: FALSE)
With TRUE the block indicates that it is active and that it writes setpoints to the axis.
bCommandAborted : BOOL (Default: FALSE)
If this is TRUE, the block was aborted by another.
bError : BOOL (Default: FALSE)
TRUE indicates that an error has occurred in the function block.
iErrorID : SMC_Error (INT )
Error number