L-force | PLC Designer - SoftMotion

The SoftMotion drive interface

Drive element <BusInterfaceName>Drive.lib

52

L

DMS 5.2 EN 03/2011 TD17

3.3.1.5

Configured parameters during start-up

ECSxM axis module (Motion)

Servo Drive 9400 StateLine

Parameter / code

Value set during start-up

Description

Sync generator:

PLC / sync device

Sync generator:

1. drive

C0043

0

0

Reset error

C0352

0

0

CAN slave

C0353/1

0

0

Addressing mode

C0356/3

Cycle time

Cycle time

PDO cycle

C0356/4

0

0

Delay time PDO

C1120

1

0

Sync mode

C1121

Cycle time

Cycle time

Sync cycle

C0367

128

129

Sync Rx-ID

C0368

128

128

Sync Tx-ID

C1123

Cycle time/2

Cycle time/2

Sync time slot

C0369

0

Cycle time

Sync generator cycle

C0366

1

1

Sync response

C5000

7

7

Operating mode

C0003

1

1

Save parameters

C0135

0

0

Control word

Parameter /

index [hex] /

code

Value set during start-up

Description

Sync generator:

PLC / sync device

Sync generator:

1. drive

6040

hex

0

Control word

1006

hex

60C2

hex

C01121, C01130

Cycle time

Sync cycle

1005

hex

80

hex

(128

dec

)

40000080

hex

(1073741952

dec

)

Addressing mode

1400

hex

...

1AFF

hex

PDO mapping

6092

hex

10000

hex

(65536

dec

)

feedconst_e4