MK Diamond MK-101 Pro24 User Manual

Page 36

Advertising
background image

36

(A)

Verify the cooling flow

Adjusting Clamp is open. If flow

exists, go to Step B.

(B)

Remove the Cooling Transfer

Tube from the Blade Guard

inlet. Go to Step C.

(C)

Place Pump into a bucket of

water and check flow. If flow

exists, go to Step D.

(D)

Remove the Cooling Transfer

Tube and check for flow. If flow

exists, refer to water pump

manual.

(E)

Remove the Blade Guard

Intake Fitting. Go to Step F.

(F)

Remove the Cooling Channel

cover screws. Go to step G.

(G)

Rod the Cooling Channels

and then recheck flow.

NOTE: “Rodding” cooling channels is performed by inserting a

small wire rod through the cooling inlet on top of the Blade Guard

and directing the rod out through each of the cooling flow tubes

located on the underside o the Blade Guard. The cooling chan-

nels should be “rodded” until all ports are free of foreign debris.