MK Diamond MK-212 User Manual
Page 32

32
MK-212 SAW
MAINTENANCE
COOLING FLOW
(B)
Remove the Cooling Transfer
Tube from the Blade Guard inlet.
(A)
Verify the cooling flow Adjusting
Clamp is open.
(C)
Place Pump into a bucket of water
and check flow.
(E)
Remove the Pump Discharge
Fitting and check for flow.
(D)
Remove the Cooling Transfer
Tube and check for flow.
(F)
Remove the Pump Intake Screen
and check for debris – clean the
screen if necessary.
NOTE: “Rodding” cooling channels is performed by inserting a small wire rod through the cooling
inlet on top of the Blade Guard and directing the rod out through each of the cooling flow tubes lo-
cated on the underside of the Blade Guard. The cooling channels should be “rodded” until all ports
are free of foreign debris.
(G)
Rod (clean out) the Cooling
Manifold and then recheck flow.