Brother BES-1261BC User Manual

Page 143

Advertising
background image

Chapter 8 Standard Adjustment

BES-961BC

BES-1261BC

141

1.

Dismount the pulley cover and turn the pulley B

q

until the pulley scale indicates 180˚ and the

needle bar is set at the lowest position. (The pulley B "2" mark and the stop mark "2" are aligned.)

2.

Insert the positioning bar

w

into the hole of the pulley

q

and fix the drive shaft.

Note) Turn the pulley B securely in the clockwise direction to eliminate a backlash.

3.

Loosen the needle bar clamp set screw

e

and the bolt

u

of the top dead center stopper

t

when

the needle tip is positioned 10.8 mm above the center of the rotary hook shaft. Adjust the position of
the needle bar thread guide so that the set screw

r

on it is turned to the right by 25 ~ 30˚. Tighten

the needle bar clamp set screw

e

securely.

Note) When tightening the needle bar clamp set screw

e

, the hole in the needle bar guide should face the front.

4.

After adjustment is finished, remove the positioning bar

w

.

5.

Set the needle bar at the highest position (where the pulley B indication mark "1" and the cover
indication mark "1" are aligned). Lightly press the top dead center stopper

t

toward the cushion

rubber

y

, and tighten the top dead center stopper bolt

u

while pressing down the needle bar clamp

so that it faces the front.

Note) • Make sure that the top dead center stopper does not hit the needle bar guide rail

i

at this time.

• When tightening the upper dead point stopper bolt

u

, insert the longer side of the attached wrench into the

bolt and tighten it by using the shorter side.
Excessive tightening may make the needle bar movement sluggish.

Advertising