background image

AutoMax DCSNet/RE RIO Module Page

27

Publication number 56AMXN-UM002A-EN-P November 2002

Figure 7 Module Properties Dialog 1

4. Assign the module a Name and optionally a Description.

5. Set the Comm Format to Data – INT – with Status.

6. Set the Slot to match the slot number of the module in the chassis.

7. The Input Assembly Instance should be 1. The size should be large

enough to allow all the data to be passed (or larger). The maximum
size is 250 words. The minimum size is determined by the largest
offset assigned to input data.

8. The Output Assembly Instance should be 2. The size should be large

enough to allow all the data to be passed (or larger). The maximum
size is 248 words. The minimum size is determined by the largest
offset assigned to output data.

9. The Configuration Assembly Instance should be 4. The size should

be 4.

10. The Status Input Assembly Instance should be 5. The size should be

large enough to allow all the data to be passed (or larger). The
maximum size is 250 words. For Remote I/O master operation, set
the size to 1.

11. The Status Output Assembly Instance should be 6. You cannot set

the size.

12. Click Next > to display the second Module Properties – Local dialog

box