AutoMax DCSNet/RE RIO Module Page

59

Publication number 56AMXN-UM002A-EN-P November 2002

Active Drop List

The Active Drop List shows which DCS drops are active on the network.

For Remote I/O operation, only drops 1-7 are valid.

The Debug Log

The firmware on the module sends trace messages that indicate its
internal state of operation and show any minor errors it encounters.
These messages are often useful for determining why connections have
errors or for technical support.

To display these messages, select View/Monitor Debug Log. The
messages will be displayed in the main 56AmxnMon window.

To clear the log, select Monitor/Clear Debug Log.

To copy the contents of the Debug Log to the Windows clipboard so that
they can be pasted into another application, select Edit/Select All and
Copy.

Figure 20 Debug Log

The Copy Table

The Copy Table applies only to the 56AMXN/A and not to the
56AMXN/B.