Gross/Net, Span, Inverted

By means of the Gross/Net parameter, you determine whether the value for the Span is a gross
value or a net value (gross value minus current tare

).

By means of the Span parameter, you determine the measured value range which is represented
by the current output.
− The span must be entered in the selected unit.

− If you have selected Gross, you can enter values between 1 % and 100 % of the maximum cell

load.

− If you have selected Net, you can enter values between 1 % of the maximum cell load and the

value of the maximum cell load minus the current tare.

If you select Inverted

normal, the measured value 0 is converted into the start value of the

current

output and the Span is converted into the end value (for the Strain Gauge Converter

always +20 mA). If you select Inverted

inverted, the Span is converted into the start value of

the current output and the measured value 0 is converted into the end value.

Fault current

——

Min

Max

Hold

Up/down

Inverted

——

Normal

Inverted