The commands must be encoded as follows:
The
Strain Gauge Converter returns the following responses:
Explanations:
•
Address: The address must be calculated as follows: 128 + setting under Service
→ RS 485 (see
section 7.8). Values from 128 + 0 to 128 + 31, i. e. from 10000000
Bin
to 10011111
Bin
, are possible.
•
Checksum: The checksum is calculated as follows: 100
Hex
- (1
st
byte + ... + penultimate byte of the
code), e. g. for Check_1 for address 17: 100
Hex
- (91
Hex
+ 1) = 6E
Hex
= 01101110
Bin
•
The figure 9 in the response to Check_1 refers to the device type
Strain Gauge Converter.
•
Value: in the signed long data format (4 bytes or 2 bytes)
Command
1
st
byte
2
nd
byte
3
rd
byte
4
th
byte
5
th
byte
6
th
byte
Null
0
0
0
0
0
0
Check_1
Address
1
Checksum
Get_value_ch1
Address
B
Hex
Checksum
Get_value_ch2
Address
C
Hex
Checksum
Get_value_ch3
Address
10
Hex
Checksum
Get_current
Address
D
Hex
Checksum
Command
1
st
byte
2
nd
byte
3
rd
byte
4
th
byte
5
th
byte
6
th
byte
Check_1
Address
9
Checksum
Get_value_ch1
Address
Value
Checksum
Get_value_ch2
Address
Value
Checksum
Get_value_ch3
Address
Value
Checksum
Get_current
Address
Value
Checksum