Front panel, Display mode and error messages – Rockwell Automation 937CU-AISTR-DC1 Strain Gauge Converter Installation Instructions User Manual

Page 9

Advertising
background image

7

Bul. 937

C Strain Gauge Converter Installation Instructions

Front panel

On the front panel of the Strain Gauge Converters you will find:
• LED ERR (red) to indicate

− a sensor fault (flashes red)

− the simulation mode (only when using FDT flashes red)− a

device fault (steady red)

• PWR LED (green), to indicate the presence of the supply voltage
• LED OUT 1 (yellow), to indicate that relay 1 is active
• LED OUT 2 (yellow), to indicate that relay 2 is active
• serial RS 232 interface to connect to a PC for parameterisation and

diagnosis of the Strain Gauge Converter using

FDT.

• a display for measured value and error message display and for

display during parameterisation mode

• four buttons for parameterisation of the Strain Gauge Converters

− S (Up)

− T (Down)

− ESC (Escape)

− OK

Display mode and error messages

Measured value display

• In normal operation, the current net value is indicated on the display in the selected unit.
• If you hold down the T key, the current gross value is indicated on the display in the selected unit.
• If you hold down the S key, the mV value actually measured by the Strain Gauge Converters on

the terminals 1 and 2 is indicated on the display.

• As usual, the following applies: net value = gross value - tare