Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual
Page 165

5–55
Programming Parameters
Publication 1397-5.0 — June, 2001
OUTPUT CONFIG
[Anlg Out 2 Zero] — P.149
Removes any hardware-introduced offset
from the Analog 2 output signal at the
regulator board terminal strip.
Display/Drive Units:
Numeric
Parameter Type:
Tunable
Group:
Output Config
Factory Default:
0
Minimum Value:
–200
Maximum Value:
200
[Anlg Out 3 Gain] — P.150
Only used if the I/O Expansion kit is installed.
Adjusts analog output 3 (terminals 54 and 55
on the I/O Expansion board) to allow it to
produce a signal from 5.0 to approximately
13.0 V DC.
Display/Drive Units:
VDC
Parameter Type:
Tunable
Group:
Output Config
Factory Default:
1.00
Minimum Value:
0.500
Maximum Value:
1.300
This is typically used to adjust the 10 V full scale output to match the input voltage requirement of attached equipment. For example, this
parameter would be set to 0.800 to match the requirements of equipment that accepts a 0 to 8 V DC signal.
The outputs are only rated to 10 V DC, so gain adjust values greater than 1.000 might cause the analog output circuit to saturate.