Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual
Page 185

5–75
Programming Parameters
Publication 1397-5.0 — June, 2001
OWNERS
[Stop Owner] — P.214
This parameter displays which adapters are
presently issuing a valid stop command.
Display/Drive Units:
Numeric/Text
Parameter Range:
Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6
Parameter Type:
Read Only
Group:
Owners
Minimum Value:
00000000000000000
Factory Default:
00000000000000000
Maximum Value:
0000000001111111
[Start Owner] — P.215
This parameter displays which adapters are
presently issuing a valid run command.
Display/Drive Units:
Numeric/Text
Parameter Range:
Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6
Parameter Type:
Read Only
Group:
Owners
Minimum Value:
0000000000000000
Factory Default:
0000000000000000
Maximum Value:
0000000001111111
[Direction Owner] — P.216
This parameter displays which adapter
currently has exclusive control of direction
changes.
Display/Drive Units:
Numeric/Text
Parameter Range:
Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6
Parameter Type:
Read Only
Group:
Owners
Minimum Value:
0000000000000000
Factory Default:
0000000000000000
Maximum Value:
0000000001111111