Installing the 1785ĆKA5

Communication Adapter Module

Chapter 2

2-6

Setting the DH+ Station Address
Set switches 3-8 of SW-2 to the DH+ station address for the 1785-KA5.
Valid addresses are 0-77 octal Set the switches as follows:

Most significant octal digit (switches 3Ć5)

To set to

Set switch 3 to

Set switch 4 to

Set switch 5 to

0

0

0

0

1

0

0

1

2

0

1

0

3

0

1

1

4

1

0

0

5

1

0

1

6

1

1

0

7

1

1

1

Least significant octal digit (switches 6Ć8)

To set to

Set switch 6 to

Set switch 7 to

Set switch 8 to

0

0

0

0

1

0

0

1

2

0

1

0

3

0

1

1

4

1

0

0

5

1

0

1

6

1

1

0

7

1

1

1

For example
To set the module’s DH+ station address to 64 octal, set the switches as
shown below: