Pattern Error Counter

The number of pattern errors occurring during the current
test. This will only display when Pattern Test reads

Locked Seconds

or

Relocked Seconds.

0

CRC (or CRC4) Errors

The number of CRC (or CRC4) errors occurring during the
current test.

0

Code Violations

The number of Code Violations occurring during the
current test.

0

Out of Frame Event

Indicates 2 bits out of 4 bits framing errors for both ESF
and D4 modes

0

Frame Error Event

Indicates 2 bits out of 4 bits framing errors

0

Last Self Test Result

The result of the last test performed. Read only.
Options:
Self Test Passed
Error nn (0 to 5)

0 (if no self-test
has been
performed)

Next Test (port, fraction)

The next test to run is set in this field. Options:
1. Self Test†
3. Loop NET
4. Loop Payload*
5. Loop Up Remote *
6. Loop Down Remote*
7. QRW Pattern*
8. 1:7 Pattern*
9. 3:24 Pattern*
10. 1:1 Pattern*
11. All 1s Pattern*
12. All 0s Pattern*
13. 1:2 Pattern*
14. 1:4 Pattern*
15. User 1 Pattern*
16. User 2 Pattern*
17. Smart Jack Set‡
18. Smart Jack Reset‡
19. Lamp Test†

*All of these tests offer the option of selecting which

fraction of the T1/E1 signal the test applies to (NET1,
NET2). FULL applies to the entire T1/E1 signal
(including IDLE timeslots).

Self Test

Next Test Length

The length of the next test is set in this field.
15 min., 1 min., 60 min., Unlimited
With the Self Test, Loop Up Remote and Loop Down
Remote, this parameter does not apply.

Unlimited

Full Bandwidth Loop Code The Loop code to use in the next test is set in this field.

Options: Standard, Alternate, Disabled

Standard

Fractional Loop Code

The Loop code to use in the next test is set in this field.
Options: Standard, Alternate, Disabled, and ITU-T V.54

Standard