Troubleshooting

11

T

ROUBLESHOOTING

THE

U

NIT

This section describes problems you may encounter and provides suggested methods to troubleshoot
and resolve the problems.

U

NIT

P

ROBLEMS

A list of possible problems is given in

Table 11-1

, along with suggested solutions for each.

Table 11-1 Unit Problems (1 of 4)

Symptom

Probable Cause

Solution

The LRU4240 does not power up.

• Unit not plugged in.

• Loose power connector.

• PDU (Power Distributor Unit)

isn’t powered up/on.

• Blown fuse on LRU4240.

• Reversed power leads from DC

supply (standalone).

• Make sure the unit is plugged into a

live AC outlet, if the unit is AC
powered. If the shelf is DC
powered, make sure the respective
DC leads are not crossed.

• Check to assure that all fuses are

operational; replace as needed. If
the problem persists, call Black
Box Technical Support for
assistance.

The LRU4240 system does not
dial out when an alarm occurs.

• Miscellaneous configuration on

Alarm Menu-8C.

• Modem strings 8E not correct.

• Wrong cable.

• No modem attached.

• Make sure the connection between

the COMM Port and the modem is
a crossover (null) modem
connection.

• A DCE Port is represented the same

way as the modem port.

• Make sure Connection is set to

Modem and two valid telephone
numbers are set in Phone Number 1
and Phone Number 2 in Menu-8C.

• Make sure Block all Alarms is set

to No in Menu-8A and the
occurring alarm is set to Enabled.

• If the above solutions do not

correct the problem, call Black Box
Technical Support for assistance.