5. Select the Test Length:
The length of the test can be smaller than the time between two ping messages as specified
in the previous step. If it is, only one ping is sent.
6. Select the test packets length.
From the minimum to the maximum allowed packet length (0 byte to 1500 bytes).
7. Press S to start the test
The Dual Trunk E1 Router begins sending ping messages at the specified intervals.
Press the E key to terminate the test at any time.
The results of this test are:
• Number of packets sent
• Number of packets received
• Number of errored packets
• Number of missing packets
• Average round trip delay