Configuring the KFC15 Module

1747-5.34 - June 1998

Table 2-3: Bank S3 DIP Switches

DIP
Switch

Parameter

Description

Switch 1

Duplicate
detect

off = Duplicate detect off (default)
on = Duplicate detect on

Switch 2

Error detect

off = CRC error check (default)
on = BCC error check

Switch
3-4

Number of
retries

Number of
allowable
retries per
attempt on the
RS-232C link:
00 - 07

SW3

on
off
on
off

SW4

on
on
off
off

Number of retries

0
1
2

3 (default)

Switch
5-8

DF1 ACK
time-out

The time to wait
for an ACK from
the host
computer.

SW5

on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off

SW6

on
on
off
off
on
on
off
off
on
on
off
off
on
on
off
off

SW7

on
on
on
on
off
off
off
off
on
on
on
on
off
off
off
off

SW8

on
on
on
on
on
on
on
on
off
off
off
off
off
off
off
off

Time

Out

.2
.4
.6
.8

1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0

3.2 (default)