C-4
DF1 Diagnostic Command Support
1747-5.34 - June 1998
Table C.8: Reply Values
Diagnostic Counter Reset
This command resets the diagnostic counters listed above.
Table C.9: Command Format
Data Byte
Description
Status Reply
1
Mode/Status Byte
00 (No Modes)
2
Interface/Processor Type
Bits 0 – 3: Interface type
(E = Extended)
Bits 4 – 7: Processor type
(F = Computer)
FE (Extended)
3
Extended Interface Type
5F (KFC15) 60 (KFCD15)
4
On-line/Off-line Mode
0 = on-line; 1 = off-line
5
Series/Revision
Bits 0–4:
Bits 5–7:
0 = Revision A
1 = Revision B, etc.
0 = Series A
1 = Series B, etc.
6 – 16
Bulletin Name =
ASCII
“1770-KFC15 ”
“1770-KFCD15 ”
17 – 24
Reserved for factory use only
Values may vary
1 byte
1 byte
2 bytes
1 byte
CMD
06
STS
TNS
FNC
07