The following sample programs show you how to use your analog
module efficiently when operating with a programmable controller.

These programs show you how to:

configure the module

read data from the module

update the module’s output channels (if used)

These programs illustrate the minimum programming required for
communication to take place.

PLCĆ3 Programming

Block transfer instructions with the PLC-3 processor use one binary
file in a data table section for module location and other related data.
This is the block transfer control file. The block transfer data file
stores data that you want transferred to your module (when
programming a block transfer write) or from your module (when
programming a block transfer read). The address of the block
transfer data files are stored in the block transfer control file.

The same block transfer control file is used for both the read and
write instructions for your module.
A different block transfer
control file is required for every module.

A sample program segment with block transfer instructions is shown
in Figure 3.1, and described below.

Figure 3.1

PLCĆ3 Family Sample Program Structure for a 1794ĆIE8 Module

EN

BTR
BLOCK XFER READ

RACK:

GROUP:
MODULE:

CONTROL:

7

0
0

#B3:0

DATA FILE:
LENGTH:

#B4:0

9

EN

BTW
BLOCK XFER WRITE

RACK:
GROUP:
MODULE:
CONTROL:

7
0
0

#B3:0

DN

DATA FILE:
LENGTH:

#B5:0

1

B3:0

05

Block Transfer

Read Done Bit

ER

Enable

Done

Error

12

15

13

Enable

Done

Error

02

05

03

Block Transfer

Write Done Bit

1

2

DN

ER

B3:0

15

Program Action

At powerĆup in RUN mode, or when the

processor is switched from PROG to RUN,

the user program enables a block transfer

read. Then it initiates a block transfer write

to configure the module if the powerĆĆup bit

is set.
Thereafter, the program continuously

performs read block transfers.
Note: You must create the data file

for the block transfers before you

enter the block transfer instructions.

The pushbutton allows the user to

manually request a block transfer write to

configure the module.

B4:8

15

Pushbutton

PowerĆup Bit

1

1

PowerĆup bit included in Series B modules only.

Sample programs for Flex

I/O Analog Modules