3–3

Module Programming

Publication 1794Ć6.5.2 - May 1996

Figure 3.2

PLCĆ3 Family Sample Program Structure for a 1794ĆOE4 Module

EN

BTR
BLOCK XFER READ

RACK:

GROUP:
MODULE:

CONTROL:

7

1
0

#B6:0

DATA FILE:
LENGTH:

#B7:0

1

EN

BTW
BLOCK XFER WRITE

RACK:
GROUP:
MODULE:
CONTROL:

7
1
0

#B6:0

DN

DATA FILE:
LENGTH:

#B8:0

14

B6:0

05

Block Transfer

Read Done Bit

ER

Enable

Done

Error

12

15

13

Enable

Done

Error

02

05

03

Block Transfer

Write Done Bit

1

DN

ER

B6:0

15

Program Action

At powerĆup in RUN mode, or when the

processor is switched from PROG to RUN,

the user program enables a block transfer

read. Then it initiates a block transfer write

to configure the module and send data

values.
Thereafter, the program continuously

performs read block transfers and write

block transfers.
Note: You must create the data file

for the block transfers before you

enter the block transfer instructions.

2

Figure 3.3

PLCĆ3 Family Sample Program Structure for a 1794ĆIE4XOE2 Module

EN

BTR
BLOCK XFER READ

RACK:

GROUP:
MODULE:

CONTROL:

7

2
0

#B9:0

DATA FILE:
LENGTH:

#B10:0

5

EN

BTW
BLOCK XFER WRITE

RACK:
GROUP:
MODULE:
CONTROL:

7
2
0

#B9:0

DN

DATA FILE:
LENGTH:

#B11:0

8

B9:0

05

Block Transfer

Read Done Bit

ER

Enable

Done

Error

12

15

13

Enable

Done

Error

02

05

03

Block Transfer

Write Done Bit

1

2

DN

ER

B9:0

15

Program Action

At powerĆup in RUN mode, or when the

processor is switched from PROG to RUN,

the user program enables a block transfer

read. Then it initiates a block transfer write

to configure the module and send data valĆ

ues
Thereafter, the program continuously

performs read block transfers and write

block transfers.
Note: You must create the data file

for the block transfers before you

enter the block transfer instructions.

Advertising