Worksheet d ktcs switch settings – Rockwell Automation 1784-KTCS ControlNET Scanner Installation Instructions User Manual

Page 10

Advertising
background image

10

ControlNet Scanner Card

Publication 1784-5.35 – April 1999

Worksheet D
KTCS switch settings

Base I/O Address

(hex)

Switch Settings

Base I/O Address

(hex)

Switch Settings

200

potential device
conflict: game port

up (1)

down (0)

1 2 3 4

300

potential device
conflict:
prototype cards

up (1)

down (0)

1 2 3 4

220

factory-set default
address &
recommended setting

up (1)

down (0)

1 2 3 4

320

potential device
conflict: HDD

up (1)

down (0)

1 2 3 4

240

up (1)

down (0)

1 2 3 4

340

up (1)

down (0)

1 2 3 4

260

up (1)

down (0)

1 2 3 4

360

up (1)

down (0)

1 2 3 4

280

up (1)

down (0)

1 2 3 4

380

potential device
conflict: SDLC

up (1)

down (0)

1 2 3 4

2A0

up (1)

down (0)

1 2 3 4

3A0

potential device
conflict: SDLC

up (1)

down (0)

1 2 3 4

2C0

potential device
conflict: EGA

up (1)

down (0)

1 2 3 4

3C0

potential device
conflict: EGA

up (1)

down (0)

1 2 3 4

2E0

potential device
conflict: GPIB

up (1)

down (0)

1 2 3 4

3E0

up (1)

down (0)

1 2 3 4

Advertising