The operating parameters describe the environment within the KTCS slot.
Refer to the documentation for your computer for environmental requirements.
The card should not exceed those specifications.

General Specifications

Characteristic

Value

Power
Requirements

5V dc, 640mA Maximum

Conductor

Category 2

1

Environmental Specifications

Operating

Nonoperating

Slot Temperature

0 to 50

°

C (32 to 122

°

F)

– 40 to 85

°

C (– 40 to 185

°

F)

Humidity

5 to 95% without condensation

5 to 95% without condensation

Vibration

10 to 150 Hz, constant .012 in
displacement

10 to 150 Hz, constant 2.0G
acceleration

not applicable

Shock

30G peak/11 ms

50G peak/11 ms

Agency Certification

(when product or packaging is marked)

Class 1, Division 2
Groups A, B, C, D

П

П

П

П

ПП

ПП

П

П

marked for all applicable directives

1

Refer to the Industrial Automation Wiring and Grounding Guidelines for Noise Immunity,
publication 1770-4.1