Rockwell Automation 2706-P42R_P42C_P43R_P43C_P44R_P44C_P72CNx_P74CNx InView Marquee Message Display User Manual
Page 16
 
Publication 2706-IN006E-EN-P
InView Marquee Message Display 15
4. If the sign is to be used with serial communications, remove one
or both of the hole plugs from the lowest holes on the right end 
of the sign case. Otherwise, proceed to Step 6.
9. Connect the incoming serial wires per pinout.
TB1 can be used for incoming RS-485 or RS-232 serial 
connection. They cannot be connected at the same time.
RS-485 is recommended to reduce undesirable electrical 
interference.
Power connection
LINE 1
GR
OUND
LINE 2 OR
NEUTRAL
LINE 1
GR
OUND
LINE 2 OR
NEUTRAL
208 - 240 VAC INPUT
Neutral
(Line 2):
Line
(Hot)
Ground
GREEN 
w/
Serial device hole 
plug/opening
Right-end view
TIP
TB1 can be used for incoming serial connection for 
RS-232 or RS-485. The full pinout diagram is shown 
below:
TB1 - Full
1. GND
5. RS-485(+)
2. +5V
6. RS-485(-)
3. RS-232 TX
7. NC
4. RS-232 RX
8. SHIELD
TB1 - RS-485
1. NC
5. RS-485(+)
2. NC
6. RS-485(-)
3. NC
7. NC
4. NC
8. SHIELD