4. If the sign is to be used with serial communications, remove one

or both of the hole plugs from the lowest holes on the right end
of the sign case. Otherwise, proceed to Step 6.

9. Connect the incoming serial wires per pinout.

TB1 can be used for incoming RS-485 or RS-232 serial
connection. They cannot be connected at the same time.

RS-485 is recommended to reduce undesirable electrical
interference.

Power connection

LINE 1

GR
OUND

LINE 2 OR

NEUTRAL

LINE 1

GR
OUND

LINE 2 OR

NEUTRAL

208 - 240 VAC INPUT

Neutral

(Line 2):

Line

(Hot)

Ground

GREEN
w/

Serial device hole
plug/opening

Right-end view

TIP

TB1 can be used for incoming serial connection for
RS-232 or RS-485. The full pinout diagram is shown
below:

TB1 - Full

1. GND

5. RS-485(+)

2. +5V

6. RS-485(-)

3. RS-232 TX

7. NC

4. RS-232 RX

8. SHIELD

TB1 - RS-485

1. NC

5. RS-485(+)

2. NC

6. RS-485(-)

3. NC

7. NC

4. NC

8. SHIELD