Address
A serial address for an InView sign is a number from 1 to 254 in 
hexadecimal (01 to FE). All signs leave the factory with a default 
address of 1 or 01.
The serial address is set in the messaging software and downloaded to 
the display with the InView applications.
Checkout Procedure
After installing a sign according to the Electrical and Mounting 
Instructions, make sure the sign is installed properly by applying 
power to it. The following information should be displayed on the 
sign:
•
firmware part number and version letter (e.g., xxxx),
•
amount of RAM in the sign, (e.g., 256K), and
•
serial address of the sign (a number from 01 to FE or from 1 to 
254).
Electrical Connections 
2706-P42, 2706-P43 and 
2706-P44 
Connecting the power wires
1. Remove the power supply cover by unscrewing its 6 screws.
Save the screws for a later step.
2. It is recommended that you install power and serial wires at the
bottom of the power supply enclosure. However, to 
accommodate power or serial wire installation at the top of the 
enclosure, you may want to remove the left or right conduit hole 
plug from the top of the enclosure by removing its wing nut 
inside the enclosure. Save the hole plug for a later step.
ATTENTION
!
Hazardous voltage. Contact with high voltage may 
cause death or serious injury. Always disconnect 
power to sign prior to servicing.
Hole plugs, 
top, removed
Hole plugs, left, 
removed
Wing nuts for 
hole plugs